Repositório do Conhecimento Institucional do Centro Universitário FEI
 

Electronic system for data acquisition to study radiation effects on operating MOSFET transistors

dc.contributor.authorDE OLIVEIRA, J. A.
dc.contributor.authorDE MELO, M. A. A.
dc.contributor.authorMarcilei Aparecida Guazzelli
dc.contributor.authorMEDINA, N. H.
dc.contributor.authorOrcidhttps://orcid.org/0000-0001-7110-7241
dc.date.accessioned2022-01-12T22:00:58Z
dc.date.available2022-01-12T22:00:58Z
dc.date.issued2014-09-01
dc.description.abstract© 2014 AIP Publishing LLC.In this work we present the development of an acquisition system for characterizing transistors under X-ray radiation. The system is able to carry out the acquisition and to storage characteristic transistor curves. To test the acquisition system we have submitted polarized P channel MOS transistors under continuous 10-keV X-ray doses up to 1500 krad. The characterization system can operate in the saturation region or in the linear region in order to observe the behavior of the currents or voltages involved during the irradiation process. Initial tests consisted of placing the device under test (DUT) in front of the X-ray beam direction, while its drain current was constantly monitored through the prototype generated in this work, the data are stored continuously and system behavior was monitored during the test. In order to observe the behavior of the DUT during the radiation tests, we used an acquisition system that consists of an ultra-low consumption16-bit Texas Instruments MSP430 microprocessor. Preliminary results indicate linear behavior of the voltage as a function of the exposure time and fast recovery. These features may be favorable to use this device as a radiation dosimeter to monitor low rate X-ray.
dc.description.firstpage130
dc.description.lastpage134
dc.description.volume1625
dc.identifier.citationDE OLIVEIRA, J. A.; DE MELO, M. A. A.; GUAZZELLI, M,. A. Electronic system for data acquisition to study radiation effects on operating MOSFET transistors. AIP Conference Proceedings, 1625, p. 130-134, 2014.
dc.identifier.doi10.1063/1.4901778
dc.identifier.issn1551-7616
dc.identifier.urihttps://repositorio.fei.edu.br/handle/FEI/4036
dc.relation.ispartofAIP Conference Proceedings
dc.rightsAcesso Aberto
dc.subject.otherlanguageData acquisition system
dc.subject.otherlanguageFourier analyses
dc.subject.otherlanguageLow power consumption
dc.subject.otherlanguageMOSFET noise
dc.subject.otherlanguageTotal Ionizing Dose
dc.titleElectronic system for data acquisition to study radiation effects on operating MOSFET transistors
dc.typeArtigo de evento
fei.scopus.citations1
fei.scopus.eid2-s2.0-84911442519
fei.scopus.updated2025-02-01
fei.scopus.urlhttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84911442519&origin=inward

Arquivos