Aquisição de eletrocardiograma e classificação de arritmias por machine learning

dc.contributor.advisorCastro, Maria Claudia F.pt_BR
dc.contributor.advisorLatteshttp://lattes.cnpq.br/7429780004238103pt_BR
dc.contributor.authorSilva, César Nogueira
dc.contributor.authorMatos, Jefferson Almeida
dc.contributor.authorLopes, Fernanda Ferrezi
dc.date.accessioned2022-09-05T20:28:22Z
dc.date.available2022-09-05T20:28:22Z
dc.date.issued2022-08-30
dc.description.abstractEsse projeto apresenta uma proposta de um dispositivo para monitoração cardíaca pessoal. O dispositivo foi desenvolvido aplicando técnicas de Inteligência Artificial (aprendizado de máquina) para o reconhecimento de arritmias. O dispositivo informará, por meio de um e-mail, a detecção da possível arritmia à um médico ou pessoa credenciada, de modo que possa agilizar ou antecipar, um atendimento de emergência. Segundo a classificação da AAMI (Association for the Advancement of Medical Instrumentation) foram selecionadas 4 classes, sendo Normal (N), Supraventricular ectópico (SVE), Ventricular ectópico (VE) e Fusão de normal e ventriculares (F). Utilizando a base de dados MIT-BIH Arrhythmia Database e o aplicativo (app) Classification Learner do Matlab, para o treinamento, foi possível investigar vários modelos, sendo que os melhores foram o Ensemble (SubspaceKNN) e o SVM (Cubic SVM) com acurácias de 94% e 94,1%, respectivamente. Esses modelos foram selecionados para a etapa de teste, tendo o modelo Ensemble (SubspaceKNN) obtido a melhor acurácia (74,4%) e posteriormente sendo utilizado para a implementação no aplicativo de interface do usuário. Desta forma, sua implantação contribui para o desenvolvimento de inovação científicotecnológica, à medida que o equipamento apresenta características que ainda não foram totalmente implementadas no mercado e causa impacto no âmbito social, tornando-o acessível, sem a necessidade de um serviço de monitoração contínuo contratado pelo paciente.pt_BR
dc.description.abstractThis project presents a proposal for a device for personal cardiac monitoring. The device was developed by applying Artificial Intelligence (machine learning) techniques for the recognition of arrhythmias. The device will inform, by means of an e-mail, the detection of the possible arrhythmia to a doctor or accredited person, so that he can speed up or anticipate an emergency care. According to the AAMI (Association for the Advancement of Medical Instrumentation) classification, 4 classes were selected, being Normal (N), Supraventricular ectopic (SVE), Ventricular ectopic (LV) and Fusion of normal and ventricular (F). Using the MIT-BIH Arrhythmia Database and the application (app) Classification Learner from Matlab, for training, it was possible to investigate several models, the best of which were the Ensemble (SubspaceKNN) and the SVM (Cubic SVM) with accuracies of 94% and 94.1%, respectively. These models were selected for the test stage, and the Ensemble model (SubspaceKNN) obtained the best accuracy (74.4%) and was later used for implementation in the user interface application. In this way, its implementation contributes to the development of scientific-technological innovation, as the equipment presents characteristics that have not yet been fully implemented in the market and causes an impact on the social sphere, making it accessible, without the need for a monitoring service. continuous contracted by the patient.en
dc.description.sponsorshipCentro Universitário FEIpt_BR
dc.format.extent73pt_BR
dc.identifier.urihttps://repositorio.fei.edu.br/handle/FEI/4579
dc.language.isopt_BRpt_BR
dc.rightsAbertopt_BR
dc.subjectECGpt_BR
dc.subjectmachine learningpt_BR
dc.subjectarritmiapt_BR
dc.subjectMATLABpt_BR
dc.subjectarrhythmiapt_BR
dc.titleAquisição de eletrocardiograma e classificação de arritmias por machine learningpt_BR
dc.typeTrabalho de Conclusão de Cursopt_BR
fei.date.entrega2022pt_BR
Arquivos
Pacote Original
Agora exibindo 1 - 3 de 3
Carregando...
Imagem de Miniatura
Nome:
TCC_AQUISIÇÃO DE ELETROCARDIOGRAMA E CLASSIFICAÇÃO DE ARRITMIAS.pdf
Tamanho:
1.95 MB
Formato:
Adobe Portable Document Format
Descrição:
Nenhuma Miniatura disponível
Nome:
Avaliação.pdf
Tamanho:
554.6 KB
Formato:
Adobe Portable Document Format
Descrição:
Nenhuma Miniatura disponível
Nome:
termo.pdf
Tamanho:
505.17 KB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: